Descriptions:

The explosion-proof LED emergency power supply is used with explosion-proof LED emergency light fittings. The enclosure of explosion-proof LED emergency light fittings are manufactured in die-cast aluminum alloy with epoxy resin power sprayed on the surface, so that they have food anti-corrosion performance fifa 17 kostenlos herunterladen. For ensure the light fittings using life, the emergency power supply built-in inverter and high temperature nickel battery, design separate lightings herunterladen. Explosion-proof LED emergency light fittings have the function of open circuit (no load) for ensure the personal safety when installation and maintenance herunterladen.

The explosion-proof LED emergency light fittings can satisfy the requirements in Petroleum, chemical industry, medicine, war industry, food, power plants and other enterprises herunterladen.

LED Explosion-proof emergency light fittings can be sorted as: bracket lamp, platform lamp and wall lamp.

LED Explosion-proof emergency bracket type lamps can be sorted as: ceiling type, wall sunction type and chain type microsoft word free herunterladen.

The mounting ways of the LED explosion-proof emergency platform light fittings C-90° are fence type and platform flange type.

The mounting ways of the LED explosion-proof emergency platform light fittings D-25° are fence type and platform flange type herunterladen.

  • There is a feature of good electromagnetic compatibility and it does not cause interference to the system power grid.
  • It is not influenced by the voltage fluctuations and can be operated in the wide voltage range 100~240V AC
  • There is a good performance of vibration due to the LED is the solid-state light source
  • The highest class of flameproof is up to II C
  • The degree of protection is up to IP66

Main Technical Data

Certification | Ex mark | Meet the standard

China (CQST Ex) Ex de II C T6 DIP A21 TA, T6 GB3836   GB12476

Intended use: Can be used in zone 1 and zone 2, Can be used in zone 21 and zone 22
Degree of protection: IP66
Rated voltage: 100 ~ 240V AC 50/60Hz
Rated power: 30W
Recharging time: 24h
Emergency starting time: 0.1 (S)
Emergency illuminating time: > 90 (min)
Power factor: > 0.98
Ambient temperature: -40°C ≤ Ta ≤ 50°C
Terminal: 2.5mm2, PE terminal: 2 x 10mm2
Cable entry: 3 x G3/4″
Outside diameter: ϕ8-11.5mm

Order specifications

Mounting circuit diagram for emergency light fittings

Outline dimensions